BWBDF - ALTC 1004 NICAD BATTERY, SEALED, 7.2V, 1700MAH

  • MSDS: BWBDF
  • Manufacturer: ALEXANDER MFG CO
  • Product Name: ALTC 1004 NICAD BATTERY, SEALED, 7.2V, 1700MAH
  • National Stock Number: 6140-00N055371
Product Identification

Product ID:ALTC 1004 NICAD BATTERY, SEALED, 7.2V, 1700MAH
MSDS Date:12/01/1992
FSC:6140
NIIN:00N055371
MSDS Number: BWBDF

Responsible Party
ALEXANDER MFG CO
1511 S GARFIELD PL
MASON CITY, IA 50401
US

Emergency Phone: 515-423-8955

Info Phone: 515-423-1161

Cage: 56469

Contractor
ALEXANDER TECHNOLOGIES INC
1508 MASON CITY, IA 50401 US

Telephone: 515-423-1161/8955

Cage: 56469

Ingredients

NICKEL (SARA III)

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 20-30%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3


NICKEL (II) HYDROXIDE; (NICKEL HYDROXIDE) (SARA III)

CAS: 12054-48-7

RTECS: QR7040000

Fraction By Weight: 20-30%

OSHA PEL 1 MG (NI)/M3

ACGIH TLV: 0.1 MG(NI)/M3

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


CADMIUM (SARA III)

CAS: 7440-43-9

RTECS: EU9800000

Fraction By Weight: 13-15%

OSHA PEL 0.2 MG/M3 DUST; Z-2

ACGIH TLV: 0.01 MG/M3 DUST

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


CADMIUM HYDROXIDE

CAS: 21041-95-2

Fraction By Weight: 13-15%

OSHA PEL 0.05 MG CD/M3

ACGIH TLV: 0.05 MG CD/M3


POTASSIUM HYDROXIDE (SARA III)

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: 2-4%

OSHA PEL C 2 MG/M3

ACGIH TLV: C 2 MG/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:N/KTE:INHAL:DURING A FIRE INVOLVING LG
QTYS OF BATTERIES, CADMIUM FUMES MAY BE RELEASED. EYES:IF BATTERY
RUPTURES, SKIN CONT MAY COME IN CONT W/TRACT AMTS OF POTASSIUM
HYDROXIDE, WILL CAUSE A BURN. SK IN:IF BATTERY RUPTURES, SKIN CONT
MAY COME IN CONT W/TRACE AMTS OF POTASSIUM HYDROXIDE, WILL CAUSE
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NICKEL:IARC MONO ON EVAL OF CARCIN RISK
OF CHEM TO MAN, VOL 49, PG 257, 1990:GROUP 2B. NTP 7TH ANNUAL RPT
ON (SUPDAT)
Effects of Overexposure:HLTH HAZ:BURN. NOTE:MFG CONSIDERS BATTERY
"ARTICLE" AS DEFINED IN 29 CFR 1910-1200 SECTION (C). FURTHER, THIS
ARTICLE (BATTERY) DOES NOT RELEASE/OTHERWISE RSLT IN EXPOS TO HAZ
CHEM UNDER CNDTNS OF YOU R INTENDED USE. EACH CELL OF BATTERY
ISSEALED CNTNR ENCLOSING NICKEL ELECTRODE, CADMIUM ELECTRODE &
POTASSIUM (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE O*2/ARTF RESP) . EYES:IMMEDIATELY FLUSH
W/POTABLE WATER FOR MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM MD
( ). SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD .

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . WAREHOUSE OR DEPOT TYPE STORAGE.
Unusual Fire/Explosion Hazard:CADMIUM FUMES MAY BE RELEASED DURING
BURNING.

Accidental Release

Spill Release Procedures:ELECTROLYTE, POTASSIUM HYDROXIDE IS CAUSTIC.
DO NOT ALLOW SKIN/EYE CONTACT. FLUSH W/WATER. THERE IS ONLY TRACE
AMT OF POTASSIUM HYDROXIDE AVAIL IN BATTERY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT INCIN/MUTILATE; MAY BURST
RELEASING TOX MATL. (CADMIUM FUMES). DO NOT SHORT CIRCUIT BATTERY,
IT MAY CAUSE BURNS WHEN IN CONT W/SKIN OR EYES.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NOT APPLICABLE. NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Supplemental Safety and Health
EXPLAN OF CARCIN:CARCIN, 1994:ANTIC TO BE CARCIN. HUMAN:LUNGS, NASAL
CAVATIES. CADMIUM:IARC MONO, SUPP, VOL 7, PG 139, 1987:GROUP 2A.
NTP 7TH ANNUAL RPT ON CARCIN, 1994:ANTIC TO BE CARCIN. HUMAN:LUNG,
PROSTATE, RENAL SYS EFTS. EFTS OF OVEREXP:HYDROXIDE ELECTROLYTE.

Chemical Properties

HCC:N1
Evaporation Rate & Reference:NOT KNOWN

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:BURNING (FIRE), RUPTURING.
Hazardous Decomposition Products:CADMIUM FUMES MAY BE RELEASED DURING A
FIRE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE &
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.